Which data subset should be augmented for deep learning? a simulation study using urothelial cell carcinoma histopathology images

应该对哪个数据子集进行扩充以用于深度学习?一项使用尿路上皮癌组织病理图像的模拟研究

阅读:2

Abstract

BACKGROUND: Applying deep learning to digital histopathology is hindered by the scarcity of manually annotated datasets. While data augmentation can ameliorate this obstacle, its methods are far from standardized. Our aim was to systematically explore the effects of skipping data augmentation; applying data augmentation to different subsets of the whole dataset (training set, validation set, test set, two of them, or all of them); and applying data augmentation at different time points (before, during, or after dividing the dataset into three subsets). Different combinations of the above possibilities resulted in 11 ways to apply augmentation. The literature contains no such comprehensive systematic comparison of these augmentation ways. RESULTS: Non-overlapping photographs of all tissues on 90 hematoxylin-and-eosin-stained urinary bladder slides were obtained. Then, they were manually classified as either inflammation (5948 images), urothelial cell carcinoma (5811 images), or invalid (3132 images; excluded). If done, augmentation was eight-fold by flipping and rotation. Four convolutional neural networks (Inception-v3, ResNet-101, GoogLeNet, and SqueezeNet), pre-trained on the ImageNet dataset, were fine-tuned to binary classify images of our dataset. This task was the benchmark for our experiments. Model testing performance was evaluated using accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve. Model validation accuracy was also estimated. The best testing performance was achieved when augmentation was done to the remaining data after test-set separation, but before division into training and validation sets. This leaked information between the training and the validation sets, as evidenced by the optimistic validation accuracy. However, this leakage did not cause the validation set to malfunction. Augmentation before test-set separation led to optimistic results. Test-set augmentation yielded more accurate evaluation metrics with less uncertainty. Inception-v3 had the best overall testing performance. CONCLUSIONS: In digital histopathology, augmentation should include both the test set (after its allocation), and the remaining combined training/validation set (before being split into separate training and validation sets). Future research should try to generalize our results.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。