High sensitivity guided-mode-resonance optical sensor employing phase detection

采用相位检测的高灵敏度导模共振光学传感器

阅读:1

Abstract

We report an ultra-sensitive refractive index (RI) sensor employing phase detection in a guided mode resonance (GMR) structure. By incorporating the GMR structure in to a Mach-Zehnder Interferometer, we measured the phase of GMR signal by calculating the amount of fringe shift. Since the phase of GMR signal varies rapidly around the resonance wavelength, the interference fringe pattern it forms with the reference signal becomes very sensitive to the surrounding RI change. The sensitivity comes out to be 0.608π phase shift per 10(-4) RI change in water medium which is more than 100 times higher than the other reported GMR based phase detection method. In our setup, we can achieve a minimum phase shift of (1.94 × 10(-3)) π that corresponds to a RI change of 3.43 × 10(-7), outperforming any of reported optical sensors and making it useful to detect RI changes in gaseous medium as well. We have developed a theoretical model to numerically estimate the phase shift of the GMR signal that predicts the experimental results very well. Our phase detection method comes out to be much more sensitive than the conventional GMR sensors based on wavelength or angle resolved scanning methods.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。