Analytical validation of an Enzyme Immunoassay for the measurement of urinary oxytocin in dogs and wolves

对狗和狼尿液催产素进行酶联免疫测定的分析验证

阅读:8
作者:Franka S Schaebs, Sarah Marshall-Pescini, Friederike Range, Tobias Deschner

Abstract

Assessing changes in oxytocin (OT) levels in response to a variety of social stimuli has become of major interest in the field of behavioral endocrinology. OT is involved in the regulation of various aspects of social behavior such as tolerance, and the formation and maintenance of social bonds but also the regulation of stress. All of these aspects have been identified as potential targets of selection during the domestication process. Therefore, comparing the role of the oxytocinergic system in various aspects of dog and wolf social behavior, might help to understand whether this system was involved in the domestication process. Studies assessing OT levels in dogs and wolves have used invasively collected plasma and serum samples and non-invasively collected urine samples. However, when using an assay system on a new species a careful and complete validation of the method is of crucial importance, and to date no proper validation, to assess urinary OT levels in dogs and wolves, has been reported. We therefore conducted an analytical validation of an Enzyme Immunoassay (EIA) for the measurement of OT in urine of dogs and wolves, using a commercially available EIA. Stability tests revealed that OT levels degrade over time when stored at 4 °C, but are little affected by repeated thawing. In addition, our results indicate that the variance in OT levels is slightly lower when phosphoric acid is added following collection to prevent OT degradation. Long term storage tests revealed that urinary OT levels are least variable when stored as extracts in ethanol at -20 °C, rather than as unextracted urine samples. Validation results were acceptable with regard to parallelism, but values for accuracy and extraction efficiency were not meeting the standard criteria usually applied to steroid EIAs, especially when assessed for the lower range of the assay. The results of this study highlight the importance of an analytical assay validation, since even if validation parameters are not optimal, if published, they allow readers to estimate the relevance of studies using the validated method.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。