Discussion of hemodynamic optimization strategies and the canonical understanding of hemodynamics during biventricular mechanical support in cardiogenic shock: does the flow balance make the difference?

探讨心源性休克双心室机械辅助治疗期间的血流动力学优化策略和血流动力学的经典理解:流量平衡是否起决定性作用?

阅读:1

Abstract

BACKGROUND: Mechanical circulatory support (MCS) devices may stabilize patients with severe cardiogenic shock (CS) following myocardial infarction (MI). However, the canonical understanding of hemodynamics related to the determination of the native cardiac output (CO) does not explain or support the understanding of combined left and right MCS. To ensure the most optimal therapy control, the current principles of hemodynamic measurements during biventricular support should be re-evaluated. METHODS: Here we report a protocol of hemodynamic optimization strategy during biventricular MCS (VA-ECMO and left ventricular Impella) in a case series of 10 consecutive patients with severe cardiogenic shock complicating myocardial infarction. During the protocol, the flow rates of both devices were switched in opposing directions (+ / - 0.7 l/min) for specified times. To address the limitations of existing hemodynamic measurement strategies during biventricular support, different measurement techniques (thermodilution, Fick principle, mixed venous oxygen saturation) were performed by pulmonary artery catheterization. Additionally, Doppler ultrasound was performed to determine the renal resistive index (RRI) as an indicator of renal perfusion. RESULTS: The comparison between condition 1 (ECMO flow > Impella flow) and condition 2 (Impella flow > VA-ECMO flow) revealed significant changes in hemodynamics. In detail, compared to condition 1, condition 2 results in a significant increase in cardiac output (3.86 ± 1.11 vs. 5.44 ± 1.13 l/min, p = 0.005) and cardiac index (2.04 ± 0.64 vs. 2.85 ± 0.69, p = 0.013), and mixed venous oxygen saturation (56.44 ± 6.97% vs. 62.02 ± 5.64% p = 0.049), whereas systemic vascular resistance decreased from 1618 ± 337 to 1086 ± 306 s*cm(-5) (p = 0.002). Similarly, RRI decreased in condition 2 (0.662 ± 0.05 vs. 0.578 ± 0.06, p = 0.003). CONCLUSIONS: To monitor and optimize MCS in CS, PA catheterization for hemodynamic measurement is applicable. Higher Impella flow is superior to higher VA-ECMO flow resulting in a more profound increase in CO with subsequent improvement of organ perfusion.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。