Metabolic development of necrotic bone in the femoral head following resurfacing arthroplasty. A clinical [18F]fluoride-PET study in 11 asymptomatic hips

股骨头表面置换术后坏死骨的代谢发展:一项针对11例无症状髋关节的[18F]氟化物-PET临床研究

阅读:1

Abstract

BACKGROUND AND PURPOSE: One concern regarding resurfacing arthroplasty is the viability of the diminished femoral head and the postoperative risk of collapse, or a femoral neck fracture. (18)F-fluoride positron emission tomography (F-PET) enables us to assess bone viability despite there being a covering metal component. By F-PET studies, we recently showed the absence of metabolism in the remaining part of femoral heads, 1-4 years after surgery in 11 of 46 consecutive cases. We now present the further development of bone metabolism in these 11 cases. PATIENTS AND METHODS: 10 patients (11 chips) with previously shown loss of femoral head metabolism were evaluated by radiography and repeated F-PET scans, 3-6.5 years after surgery. The size of the area with low (18)F-fluoride PET uptake in the femoral head was compared to that in earlier PET images. RESULTS: No patients had any clinical symptoms; nor was any necrotic bone area visible in plain radiographs. On F-PET scans, 2 patients showed a diminished area with low uptake, 4 were unchanged, and 5 had enlarged areas. INTERPRETATION: Bone metabolism surrounding a volume of bone with no metabolic activity changes dynamically even 5 years after surgery. The presence of bone with minor uptake of F-tracer, indicating low or no bone metabolism, with further progression in 5 of 11 cases leads us to conclude that resurfacing THA should be used restrictively.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。