Uncemented custom femoral components in hip arthroplasty. A prospective clinical study of 191 hips followed for at least 7 years

髋关节置换术中非骨水泥型定制股骨假体:一项前瞻性临床研究,对 191 例髋关节进行了至少 7 年的随访。

阅读:1

Abstract

BACKGROUND AND PURPOSE: We have developed an individually designed, uncemented femoral component for achievement of improved strain distribution and fixation to the bone, to make uncemented stems more applicable in femurs of abnormal size and shape, and to improve the joint mechanics. Here we describe the design of the implant and present the results of a prospective clinical study with at least 7 years of follow-up. PATIENTS AND METHODS: The prostheses are produced by CAD-CAM technique. The design of the stem is based on CT information, and the neck design is based on the surgeon's planning of the center of rotation, femoral head offset, and leg length correction. The first-generation stem produced before 2001 had a proximal HA coating and a sand-blasted distal part that was down-scaled to avoid contact with compact bone. The second-generation stem had a porous coating beneath the HA layer and the distal part of the stem was polished. The implant was used in 762 hips (614 patients) from 1995 until 2009. 191 of these hips were followed for 7 years and 83 others were followed for 10 years, and these hips are included in the present study. Mean age at surgery was 48 (20-65) years. Congenital dysplasia of the hip was the reason for osteoarthritis in 46% and 57% of the hips in respective groups. Merle d'Aubigné score was recorded in 152 and 75 hips in the two groups. Prostheses followed for 10 years, and almost all in the 7-year group, were first-generation stems. RESULTS: The 7- and 10-year cumulative revision rates were 1.1% and 2.4%, respectively, with stem revision for any reason as endpoint. The clinical results were similar at 7 and 10 years, with Merle d'Aubigné scores of 17. Intraoperative trochanteric fissures occurred in 2 of the 191 operations (1.0%); both healed after wiring. In hips followed for 7 years, 2 periprosthetic fractures occurred; exchange of the stem was necessary in both. One additional fracture occurred between 7 and 10 years, and it was treated successfully with osteosynthesis. The rate of dislocation was 1.6% and 2.4%, respectively. There was no radiographic loosening at follow-up. INTERPRETATION: Use of a custom femoral stem gives a reliable fixation and promising medium-term clinical results in femurs of normal and abnormal shape and dimension. The individual design, which enables optimized joint mechanics, gives a low risk of mechanical complications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。