Ultrasonically guided histological and cytological fine needle biopsies of the pancreas. Reliability and reproducibility of diagnoses

超声引导下胰腺组织学和细胞学细针穿刺活检。诊断的可靠性和可重复性

阅读:1

Abstract

In 100 consecutive patients ultrasonically guided histological and cytological fine needle biopsy specimens were obtained from pancreatic lesions using two different needles with an outer diameter of 0.6 mm. Specimens taken by both cytological and histological fine needle biopsy were examined blindly by two pathologists. When related to the final and reliable diagnosis obtained in 57 patients, the predictive value of a malignant diagnosis was 1.00 for both types of biopsy. The predictive value for a benign diagnosis was 0.25 for histological specimens for both examiners and 0.33 and 0.45 for the two evaluations of the cytological specimens. False benign diagnoses seemed to be related to both sampling error and difficulties in interpreting the biopsy specimens. The intraobserver and interobserver kappa values concerning reproducibility of diagnoses were higher for histological specimens (0.80 and 0.74) than for cytological specimens (0.70 and 0.61). Consistent malignant diagnoses, however, occurred more often with cytological specimens (51 cases) than with histological specimens (39 cases) (p less than 0.05) and consistent diagnoses of insufficient material were more common with histological specimens (18 cases v six cases). Cytological fine needle biopsy seems to be the method of choice if only one method is used and a 0.6 mm needle is used.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。