Simultaneous separation of arsenic and cadmium from interfering salt matrix of multivitamin/mineral supplements by sequential coprecipitation and determination by inductively coupled plasma mass spectrometry

通过顺序共沉淀法同时分离多种维生素/矿物质补充剂干扰盐基质中的砷和镉,并用电感耦合等离子体质谱法测定

阅读:7
作者:Ermira Begu, Brittney Snell, Zikri Arslan

Abstract

Multivitamin/mineral (MVM) supplements possess highly saline matrix which, unless eliminated, precludes accurate determination of trace amounts of toxic metal impurities by inductively coupled plasma mass spectrometry (ICP-MS). Multi-step separations (up to four-steps) are described in literature; often for single element determinations due to difficulties in removing the matrix components. In this study, we developed a three-step sequential coprecipitation procedure for simultaneous separation of As and Cd impurities from MVM supplements for determination by ICP-MS. The procedure provided effective elimination of salt matrix, including Ca, Mg and KCl along with the interfering molybdenum (Mo) and tin (Sn) from MVM solutions. KCl, Mo and Sn were removed by two-step Mg(OH)2 coprecipitation to about 34 µg mL-1 K (ca. 31 µg mL-1 Cl) and 0.4 µg mL-1 Mo. Levels of Sn and Na were not significant. A third coprecipitation of the resulting MVM solution with HF + NH4OH mixture precipitated virtually all Ca and Mg to as low as 1 and 10 µg mL-1, respectively. The recoveries for As and Cd in the spiked MVM solutions were about 96% and 95%, respectively. The accuracy of the method was validated with analysis of multivitamin/multielement tablets certified reference material (SRM 3280). Experimental values were 112 ± 37 ng g-1 for 75As, and 76 ± 5, 79 ± 5, and 78 ± 7 ng g-1 for 110Cd, 111Cd and 114Cd isotopes, respectively, that were not significantly different from the certified values of As (132 ± 44 ng g-1) and Cd (80.2 ± 0.9 ng g-1) at 95% confidence level. Several commercially available MVM supplements were analyzed with the procedure. Mean As levels measured in the tablets varied between 24 and 128 ng g-1 and that for Cd were between 28 and 125 ng g-1 indicating total amount of As or Cd ingested per serving size were below the safe daily exposure limits. In addition, the results obtained for As and Cd with the procedure were lower in comparison to the values reported in literature indicating that ICP-MS analysis of complex MVM supplements could be prone to higher risks of inaccuracy without removal of interfering matrix.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。