Comparison of head tilt test between sagging eye syndrome and acquired unilateral trochlear nerve palsy

眼睑下垂综合征与后天性单侧滑车神经麻痹的头部倾斜试验比较

阅读:1

Abstract

PURPOSE: To investigate the distinction between sagging eye syndrome (SES group) and acquired unilateral trochlear nerve palsy (Trochlear group) in the Bielschowsky head tilt test (BHTT). METHODS: Fifteen patients in the SES group (mean age 74.6 ± 5.2 years) and 14 patients in the Trochlear group (55.2 ± 15.9 years) visited the Department of Ophthalmology, Hyogo Medical University Hospital between November 2016 and October 2022 for treatment of their diplopia. Eye position was measured with the alternate prism cover test, and values for fixation of the dominant eye, or unaffected eye, were used. Cyclodeviation was measured with the synoptophore and the Glaucoma Module Premium Edition of the SPECTRALIS optical coherence tomography. In the BHTT, eye position was measured in three head postures: primary position (PP), head tilt to the side with hypertropia (Hyper), and head tilt to the side with hypotropia (Hypo). The differences in vertical deviation between PP and Hyper (Hyper - PP), PP and Hypo (PP - Hypo) and Hyper - Hypo were measured and compared. RESULTS: Vertical deviation in primary position was 7.3 ± 4.5 PD in the SES group and significantly larger (17.1 ± 8.4 PD) in the Trochlear group (p = 0.002). The vertical deviation in Hyper was significantly larger in the Trochlear group with 7.7 ± 4.7 PD and 22.1 ± 9.4 PD, respectively (p < 0.001), whereas the that in Hypo was not significantly different between the two groups with 6.5 ± 3.4 PD and 8.4 ± 6.6 PD, respectively (p = 0.725). The SES group showed no significant difference according to the 3 head postures (p = 0.311), while the Trochlear group showed a significantly different with smaller mean values in vertical deviation in Hypo (p < 0.001). The difference in the vertical deviation for the 3 head postures was the largest in Hyper - Hypo (1.7 ± 2.1 PD and 13.6 ± 7.1 PD, respectively), and the accuracy of SES was at the cutoff value of 6 PD, and it was considered not to be SES if the value was 6PD or higher. The accuracy of SES determination was 100% sensitivity and 100% specificity, and the area under the curve was 1.0. CONCLUSION: The difference in Hyper - Hypo in the BHTT may be the most useful index in differentiating SES from acquired unilateral trochlear nerve palsy; if the difference was more than 6 PD, the probability of SES was very low.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。