Measurement of the retinal venous pressure with a new instrument in healthy subjects

使用新型仪器测量健康受试者的视网膜静脉压

阅读:1

Abstract

BACKGROUND: The retinal venous pressure (RVP) is a determining factor for the blood supply of the retina as well as the optic nerve head and until recently has been measured by contact lens dynamometry (CLD). A new method has been developed, potentially offering better acceptance. The applicability and the results of both methods were compared. METHODS: The type of this study is cross sectional. The subjects were 36 healthy volunteers, age 26 ± 5 years (mean ± s). Tonometry: rebound tonometer (RT) (iCare). The measurements were performed during an increase in airway pressure of 20 mmHg (Valsalva manoeuvre). Principle of RVP measurement: the central retinal vein (CRV) is observed during an increase of intraocular pressure (IOP) and at the start of pulsation, which corresponds with the RVP. Two different instruments for the IOP enhancement where used: contact lens dynamometry and the new instrument, IOPstim. PRINCIPLE: a deflated balloon of 8 mm diameter-placed on the sclera laterally of the cornea-is filled with air. As soon as a venous pulsation occurs, filling is stopped and the IOP is measured, equalling the RVP. Examination procedure: randomization of the sequence: CLD or IOPstim, IOP, mydriasis, IOP three single measurements (SM) of the IOP with RT or of the pressure increase with CLD at an airway pressure of 20 mmHg, 5 min break, IOP, and three SM using the second method at equal pressure (20 mmHg). RESULTS: Spontaneous pulsation of the CRV was present in all 36 subjects. Pressures are given in mmHg. IOP in mydriasis 15.6 ± 3.3 (m ± s). Median RVP (MRVP)) of the three SM: CLD/IOPstim, 37.7 ± 5.2/24.7 ± 4.8 (t test: p < 0.001). Range of SM: 3.2 ± 1.8/2.9 ± 1.3 (t test: p = 0.36). Intraclass correlation coefficient (ICC) of SM: 0.88/0.83. ANOVA in SM: p = 0.48/0.08. MRVP CLD minus MRVP IOPstim: 13.0 ± 5.6. Ratio MRVP CLD/MRVP IOPstim: 1.56 ± 3.1. Cooperation and agreeability were slightly better with the IOPstim. CONCLUSION: This first study with the IOPstim in humans was deliberately performed in healthy volunteers using Valsalva conditions. As demonstrated by ICC and ANOVA, reproducible SM can be obtained by both methods and the range of the SM does not differ greatly. The higher MRVP in CLD could be explained by the different directions of the force vectors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。