Comparison of Respiratory Support After Delivery in Infants Born Before 28 Weeks' Gestational Age: The CORSAD Randomized Clinical Trial

对妊娠28周前出生的婴儿分娩后呼吸支持的比较:CORSAD随机临床试验

阅读:2

Abstract

IMPORTANCE: Establishing stable breathing is a key event for preterm infants after birth. Delivery of pressure-stable continuous positive airway pressure and avoiding face mask use could be of importance in the delivery room. OBJECTIVE: To determine whether using a new respiratory support system with low imposed work of breathing and short binasal prongs decreases delivery room intubations or death compared with a standard T-piece system with a face mask. DESIGN, SETTING, AND PARTICIPANTS: In this unblinded randomized clinical trial, mothers threatening preterm delivery before week 28 of gestation were screened. A total of 365 mothers were enrolled, and 250 infants were randomized before birth and 246 liveborn infants were treated. The trial was conducted in 7 neonatal intensive care units in 5 European countries from March 2016 to May 2020. The follow-up period was 72 hours after intervention. INTERVENTIONS: Infants were randomized to either the new respiratory support system with short binasal prongs (n = 124 infants) or the standard T-piece system with face mask (n = 122 infants). The intervention was providing continuous positive airway pressure for 10 to 30 minutes and positive pressure ventilation, if needed, with the randomized system. MAIN OUTCOMES AND MEASURES: The primary outcome was delivery room intubation or death within 30 minutes of birth. Secondary outcomes included respiratory and safety variables. RESULTS: Of 246 liveborn infants treated, the mean (SD) gestational age was 25.9 (1.3) weeks, and 127 (51.6%) were female. A total of 41 infants (33.1%) receiving the new respiratory support system were intubated or died in the delivery room compared with 55 infants (45.1%) receiving standard care. The adjusted odds ratio was statistically significant after adjusting for stratification variables (adjusted odds ratio, 0.53; 95% CI, 0.30-0.94; P = .03). No significant differences were seen in secondary outcomes or safety variables. CONCLUSIONS AND RELEVANCE: In this study, using the new respiratory support system reduced delivery room intubation in extremely preterm infants. Stabilizing preterm infants with a system that has low imposed work of breathing and binasal prongs as interface is safe and feasible. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02563717.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。