Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis

用于检测人工心脏瓣膜阻塞和心内膜炎的新型成像策略

阅读:1

Abstract

Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including low-dose CT (FDG-PET) and three-dimensional transoesophageal echocardiography (3D-TEE) may have additional value. This paper reviews the role of these novel imaging tools in the field of PHV obstruction and endocarditis.For acquired PHV obstruction, MDCT is of additional value in mechanical PHVs to differentiate pannus from thrombus as well as to dynamically study leaflet motion and opening/closing angles. For biological PHV obstruction, additional imaging is not beneficial as it does not change patient management. When performed on top of 2D-TTE/TEE, MDCT has additional value for the detection of both vegetations and pseudoaneurysms/abscesses in PHV endocarditis. FDG-PET has no complementary value for the detection of vegetations; however, it appears more sensitive in the early detection of pseudoaneurysms/abscesses. Furthermore, FDG-PET enables the detection of metastatic and primary extra-cardiac infections. Evidence for the additional value of 3D-TEE is scarce.As clinical implications are major, clinicians should have a low threshold to perform additional MDCT in acquired mechanical PHV obstruction. For suspected PHV endocarditis, both FDG-PET and MDCT have complementary value.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。