Quantifying the Adhesion of Silicate Glass-Ceramic Coatings onto Alumina for Biomedical Applications

量化硅酸盐玻璃陶瓷涂层在氧化铝上的附着力,以用于生物医学应用

阅读:6
作者:Francesco Baino

Abstract

Deposition of bioactive glass or ceramic coatings on the outer surface of joint prostheses is a valuable strategy to improve the osteointegration of implants and is typically produced using biocompatible but non-bioactive materials. Quantifying the coating-implant adhesion in terms of bonding strength and toughness is still a challenge to biomaterials scientists. In this work, wollastonite (CaSiO3)-containing glass-ceramic coatings were manufactured on alumina tiles by sinter-crystallization of SiO2-CaO-Na2O-Al2O3 glass powder, and it was observed that the bonding strength decreased from 34 to 10 MPa as the coating thickness increased from 50 to 300 µm. From the viewpoint of bonding strength, the coatings with thickness below 250 µm were considered suitable for biomedical applications according to current international standards. A mechanical model based on quantized fracture mechanics allowed estimating the fracture toughness of the coating on the basis of the experimental data from tensile tests. The critical strain energy release rate was also found to decrease from 1.86 to 0.10 J/m2 with the increase of coating thickness, which therefore plays a key role in determining the mechanical properties of the materials.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。