Society of Robotic Surgery review: recommendations regarding the risk of COVID-19 transmission during minimally invasive surgery

机器人手术学会审查:关于微创手术期间 COVID-19 传播风险的建议

阅读:1

Abstract

OBJECTIVES: To determine the risk of COVID-19 transmission during minimally invasive surgical (MIS) procedures METHODS: Surgical society statements regarding the risk of COVID transmission during MIS procedures were reviewed. In addition, the available literature on COVID-19 and other viral transmission in CO2 pneumoperitoneum, as well as the presence of virus in the plume created by electrocautery during MIS was reviewed. The society recommendations were compared to the available literature on the topic to create our review and recommendations to mitigate COVID-19 transmission. RESULTS: The recommendations promulgated by various surgical societies evolved over time as more information became available on COVID-19 transmission. Review of the available literature on the presence of COVID-19 in CO2 pneumoperitoneum was inconclusive. There is no clear evidence of the presence of COVID-19 in plume created by electrocautery. Technologies to reduce CO2 pneumoperitoneum release into the operating room as well as filter viral particles are available and should reduce the exposure risk to operating room personnel. CONCLUSION: There is no clear evidence of COVID-19 virus in the CO2 used during MIS procedures or in the plume created by electrocautery. Until the presence or absence of COVID-19 viral particles has been clearly established, measures to mitigate CO2 and surgical cautery plume release into the operating room should be performed. Further study on the presence of COVID-19 in MIS pneumoperitoneum and cautery plume is needed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。