Study of the effect of Occlutech Atrial Flow Regulator on symptoms, hemodynamics, and echocardiographic parameters in advanced pulmonary arterial hypertension

研究Occlutech心房血流调节器对晚期肺动脉高压患者的症状、血流动力学和超声心动图参数的影响

阅读:1

Abstract

Optimal sized balloon atrial septostomy improves hemodynamics in advanced pulmonary arterial hypertension. Occlutech Atrial Flow Regulator is designed to provide an atrial septal fenestration diameter titrated according to the age and right atrial pressures. This observational study analyzed symptoms, exercise distance, oxygen saturations, hemodynamics and echocardiographic parameters after Atrial Flow Regulator implantation in patients with syncope or right-heart failure. Patients with high-risk predictors of mortality during septostomy were scrutinized. Thirty-nine patients (9 children) with syncope (34/39) or right-heart failure (27/39) underwent Atrial Flow Regulator implantation without procedural complications. Six-minute walk distance increased from 310 ± 158.2 to 376.4 ± 182.6 m, none developed syncope. Oxygen saturations reduced from 96.4 ± 6.4% to 92 ± 4.9% at rest and further to 80.3 ± 5.9% on exercise. Right atrial pressures reduced from 9.4 ± 5 (2-27) mmHg to 6.9 ± 2.6 (1-12) mmHg, while cardiac index increased from 2.4 ± 0.8 (0.98-4.3) to 3 ± 1 (1.1-5.3) L/min/m(2) and systemic oxygen transport increased from 546.1 ± 157.9 (256.2-910.5) to 637.2 ± 191.1 (301.3-1020.2) ml/min. Echocardiographic improvement included significant reduction of pericardial effusion and inferior caval congestion at a median follow-up of 37 months. Overall survival improved except two early and one late deaths in high-risk patients. Five of seven patients with advanced disease and key hemodynamic predictors of mortality survived. Acute hemodynamic benefits in pulmonary arterial hypertension after Atrial Flow Regulator were improved cardiac output, systemic oxygen transport, and reduced right atrial pressures. Improvement of symptoms especially syncope, exercise duration, and right ventricular systolic function as well as device patency were sustained on mid-term follow-up. Implantation was safe in all including young children without procedural complications. Mortality was noted only in patients who had high-risk predictors and patients at advanced stage of the disease.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。