An in vitro evaluation of aligner force decay in artificial saliva

人工唾液中矫正器力衰减的体外评价

阅读:1

Abstract

BACKGROUND/PURPOSE: The present study aimed to compare the force decay of invisible aligners for maxillary anterior teeth with 0.1 mm (D(1)), 0.2 mm (D(2)), and 0.3 mm (D(3)) labial movement within a simulated oral environment over 7 days. MATERIALS AND METHODS: The prepared invisible aligners were immersed in saliva (S) and subjected to applied force (F) for 7 days. The aligners were set and placed on the maxillary right central incisor with 0.1 mm (D(1)), 0.2 mm (D(2)), and 0.3 mm (D(3)) labial movement. Thin-film pressure sensors were used to measure the aligner force changes. The data were collected and analyzed by statistical methods. RESULTS: Significant differences were observed in the initial and first-day force between the D(2) and D(3) groups under simulated oral environment force (SF) (P < 0.05). There was a significant difference in force decay between Day 1 and Day 7 for all groups (P < 0.05). The SFD(1) group showed a significant decrease in force on Day 5 (P < 0.05), while the SFD(2) and SFD(3) groups showed significant force decay on Day 4 (P < 0.05). The force decay ratio on Day 7 was higher in the SFD(3) group than in the SFD(1) and SFD(2) groups, but no significant difference was observed. CONCLUSION: Larger labial movement of the aligners resulted in higher force decay under artificial saliva environments, and the force decay of invisible aligners was increased by immersion time in artificial saliva.