A comparison of lithium-substituted phosphate and borate bioactive glasses for mineralised tissue repair

锂取代磷酸盐和硼酸盐生物活性玻璃在矿化组织修复中的比较

阅读:1

Abstract

OBJECTIVES: Wnt/β-catenin signalling plays important roles in regeneration, particularly in hard tissues such as bone and teeth, and can be regulated by small molecule antagonists of glycogen synthase kinase 3 (GSK3); however, small molecules can be difficult to deliver clinically. Lithium (Li) is also a GSK3 antagonist and can be incorporated into bioactive glasses (BG), which can be used clinically in dental and bone repair applications and tuned to quickly release their constituent ions. METHODS: Here, we created phosphate (P)- and borate (B)-based BG that also contained Li (LiPBG and LiBBG) and examined their ion release kinetics and the toxicity of their dissolution ions on mouse 17IA4 dental pulp cells. RESULTS: We found that although LiPBG and LiBBG can both quickly release Li at concentrations known to regulate Wnt/β-catenin signalling, the P and B ions they concomitantly release are highly toxic to cells. Only when relatively low concentrations of LiPBG and LiBBG were placed in cell culture medium were their dissolution products non-toxic. However, at these concentrations, LiPBG and LiBBG's ability to regulate Wnt/β-catenin signalling was limited. SIGNIFICANCE: These data suggest that identifying a BG composition that can both quickly deliver high concentrations of Li and is non-toxic remains a challenge.