A fully automated, expert-perceptive image quality assessment system for whole-body [18F]FDG PET/CT

一种全自动、专家感知的全身[18F]FDG PET/CT图像质量评估系统

阅读:2

Abstract

BACKGROUND: The quality of clinical PET/CT images is critical for both accurate diagnosis and image-based research. However, current image quality assessment (IQA) methods predominantly rely on handcrafted features and region-specific analyses, thereby limiting automation in whole-body and multicenter evaluations. This study aims to develop an expert-perceptive deep learning-based IQA system for [18F]FDG PET/CT to tackle the lack of automated, interpretable assessments of clinical whole-body PET/CT image quality. METHODS: This retrospective multicenter study included clinical whole-body [18F]FDG PET/CT scans from 718 patients. Automated identification and localization algorithms were applied to select predefined pairs of PET and CT slices from whole-body images. Fifteen experienced experts, trained to conduct blinded slice-level subjective assessments, provided average visual scores as reference standards. Using the MANIQA framework, the developed IQA model integrates the Vision Transformer, Transposed Attention, and Scale Swin Transformer Blocks to categorize PET and CT images into five quality classes. The model's correlation, consistency, and accuracy with expert evaluations on both PET and CT test sets were statistically analysed to assess the system's IQA performance. Additionally, the model's ability to distinguish high-quality images was evaluated using receiver operating characteristic (ROC) curves. RESULTS: The IQA model demonstrated high accuracy in predicting image quality categories and showed strong concordance with expert evaluations of PET/CT image quality. In predicting slice-level image quality across all body regions, the model achieved an average accuracy of 0.832 for PET and 0.902 for CT. The model's scores showed substantial agreement with expert assessments, achieving average Spearman coefficients (ρ) of 0.891 for PET and 0.624 for CT, while the average Intraclass Correlation Coefficient (ICC) reached 0.953 for PET and 0.92 for CT. The PET IQA model demonstrated strong discriminative performance, achieving an area under the curve (AUC) of ≥ 0.88 for both the thoracic and abdominal regions. CONCLUSIONS: This fully automated IQA system provides a robust and comprehensive framework for the objective evaluation of clinical image quality. Furthermore, it demonstrates significant potential as an impartial, expert-level tool for standardised multicenter clinical IQA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。