Quantitative and clinical implications of the EARL2 versus EARL1 [(18)F]FDG PET-CT performance standards in head and neck squamous cell carcinoma

EARL2 与 EARL1 [(18)F]FDG PET-CT 性能标准在头颈部鳞状细胞癌中的定量和临床意义

阅读:1

Abstract

BACKGROUND: The EANM Research Ltd. (EARL) guidelines give recommendations for harmonization of [(18)F]FDG PET-CT image acquisition and reconstruction, aiming to ensure reproducibility of quantitative data between PET scanners. Recent technological advancements in PET-CT imaging resulted in an updated version of the EARL guidelines (EARL2). The aim of this study is to compare quantitative [(18)F]FDG uptake metrics of the primary tumor and lymph nodes in patients with head and neck squamous cell carcinoma (HNSCC) on EARL2 versus EARL1 reconstructed images and to describe clinical implications for nodal staging and treatment. METHODS: Forty-nine consecutive patients with HNSCC were included. For all, both EARL1 and EARL2 images were reconstructed from a singular [(18)F]FDG PET-CT scan. Primary tumors and non-necrotic lymph nodes ≥ 5 mm were delineated on CT-scan. In the quantitative analysis, maximum standardized uptake values (SUV(max)) and standardized uptake ratios (SUR(max), i.e., SUV(max) normalized to cervical spinal cord uptake) were calculated for all lesions on EARL1 and EARL2 reconstructions. Metabolic tumor volume (MTV) and total lesion glycolysis were compared between EARL1 and EARL2 using different segmentation methods (adaptive threshold; SUV2.5/3.5/4.5; SUR2.5/3.5/4.5; MAX40%/50%). In the qualitative analysis, each lymph node was scored independently by two nuclear medicine physicians on both EARL1 and EARL2 images on different occasions using a 4-point scale. RESULTS: There was a significant increase in SUV(max) (16.5%) and SUR(max) (9.6%) of primary tumor and lymph nodes on EARL2 versus EARL1 imaging (p < 0.001). The proportional difference of both SUV(max) and SUR(max) between EARL2 and EARL1 decreased with increasing tumor volume (p < 0.001). Absolute differences in MTVs between both reconstructions were small (< 1.0 cm(3)), independent of the segmentation method. MTVs decreased on EARL2 using relative threshold methods (adaptive threshold; MAX40%/50%) and increased using static SUV or SUR thresholds. With visual scoring of lymph nodes 38% (11/29) of nodes with score 2 on EARL1 were upstaged to score 3 on EARL2, which resulted in an alteration of nodal stage in 18% (6/33) of the patients. CONCLUSIONS: Using the EARL2 method for PET image reconstruction resulted in higher SUV(max) and SUR(max) compared to EARL1, with nodal upstaging in a significant number of patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。