Amyloid PET quantification using low-dose CT-guided anatomic standardization

利用低剂量CT引导解剖标准化进行淀粉样蛋白PET定量

阅读:1

Abstract

BACKGROUND: Centiloid (CL) scaling has become a standardized quantitative measure in amyloid PET because it facilitates the direct comparison of results across institutions, even when different analytical methods or tracers are used. Standard volumes of interest must be used to calculate the CL scale after the anatomic standardization of amyloid PET images using coregistered MRI; if the MRI is unavailable, the CL scale cannot be accurately calculated. This study sought to determine the substitutability of low-dose CT, which is used to correct PET attenuation in PET/CT equipment, by evaluating the measurement accuracy when low-dose CT is used as an alternative to MRI in the calculation of the CL scale. Amyloid PET images obtained using (18)F-flutemetamol from 24 patients with possible or probable Alzheimer's disease were processed to calculate the CL scale using 3D T1-weighted MRI and low-dose CT of PET/CT. CL(MRI) and CL(CT) were, respectively, defined as the use of MRI and CT for anatomic standardization and compared. Regional differences in the CT-based and MRI-based standardized anatomic images were also investigated. TRIAL REGISTRATION: Japan Registry of Clinical Trials, jRCTs031180321 (registered 18 March 2019, https://jrct.niph.go.jp/latest-detail/jRCTs031180321 ). RESULTS: A Bland-Altman plot showed that CL(CT) was slightly but significantly underestimated (mean ± standard deviation, - 1.7 ± 2.4; p < 0.002) compared with CL(MRI). The 95% limits of agreement ranged from - 2.8 to - 0.7. Pearson correlation analysis showed a highly significant correlation of r = 0.998 between CL(CT) and CL(MRI) (p < 0.001). The linear regression equation was CL(MRI) = 1.027 × CL(CT) + 0.762. In a Bland-Altman plot, Spearman correlation analysis did not identify a significant association between the difference in CL(MRI) versus CL(CT) and CL load (ρ =  - 0.389, p = 0.060). This slight underestimation of CL(CT) may derive from slightly higher uptake when the cerebellum is used as a reference area in CT-based anatomically standardized PET images versus MRI-based images. CONCLUSIONS: Low-dose CT of PET/CT can substitute for MRI in the anatomic standardization used to calculate the CL scale from amyloid PET, although a slight underestimation occurs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。