Quantitation of cancer treatment response by 2-[(18)F]FDG PET/CT: multi-center assessment of measurement variability using AUTO-PERCIST™

利用 2-[(18)F]FDG PET/CT 定量评估癌症治疗反应:使用 AUTO-PERCIST™ 进行多中心测量变异性评估

阅读:1

Abstract

BACKGROUND: The aim of this study was to assess the reader variability in quantitatively assessing pre- and post-treatment 2-deoxy-2-[(18)F]fluoro-D-glucose positron emission tomography/computed tomography ([(18)F]FDG PET/CT) scans in a defined set of images of cancer patients using the same semi-automated analytical software (Auto-PERCIST™), which identifies tumor peak standard uptake value corrected for lean body mass (SUL(peak)) to determine [(18)F]FDG PET quantitative parameters. METHODS: Paired pre- and post-treatment [(18)F]FDG PET/CT images from 30 oncologic patients and Auto-PERCIST™ semi-automated software were distributed to 13 readers across US and international sites. One reader was aware of the relevant medical history of the patients (read(reference)), whereas the 12 other readers were blinded to history but had access to the correlative images. Auto-PERCIST™ was set up to first automatically identify the liver and compute the threshold for tumor measurability (1.5 × liver mean) + (2 × liver standard deviation [SD]) and then detect all sites with SUL(peak) greater than the threshold. Next, the readers selected sites they believed to represent tumor lesions. The main performance metric assessed was the percent change in the SUL(peak) (%ΔSUL(peak)) of the hottest tumor identified on the baseline and follow-up images. RESULTS: The intra-class correlation coefficient (ICC) for the %ΔSUL(peak) of the hottest tumor was 0.87 (95%CI: [0.78, 0.92]) when all reads were included (n = 297). Including only the measurements that selected the same target tumor as the read(reference) (n = 224), the ICC for %ΔSUL(peak) was 1.00 (95%CI: [1.00, 1.00]). The Krippendorff alpha coefficient for response (complete or partial metabolic response, versus stable or progressive metabolic disease on PET Response Criteria in Solid Tumors 1.0) was 0.91 for all reads (n = 380) and 1.00 including for reads with the same target tumor selection (n = 270). CONCLUSION: Quantitative tumor [(18)F]FDG SUL(peak) changes measured across multiple global sites and readers utilizing Auto-PERCIST™ show very high correlation. Harmonization of methods to single software, Auto-PERCIST™, resulted in virtually identical extraction of quantitative tumor response data from [(18)F]FDG PET images when the readers select the same target tumor.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。