Assessing radiotracer kinetics in the Langendorff perfused heart

评估朗根多夫灌注心脏中放射性示踪剂的动力学

阅读:1

Abstract

BACKGROUND: The Langendorff perfused heart is a physiologically relevant and controllable model with potential for assessing the pharmacokinetics of new radiotracers under a range of pathophysiological conditions.. We assess the feasibility of extending the methods validated for in vivo PET data analysis to the characterisation of PET tracer kinetics applied to Langendorff perfused hearts. METHODS: Monte Carlo simulations were used to study the accuracy and reproducibility of linear and non-linear spectral analysis (SA/NLSA), the Patlak graphical method and normalised tissue activity (NA). The methods were used to analyse time-activity curves of two widely used PET tracers, [18 F]-FDG and [18 F]-FMISO, acquired ex vivo from Langendorff perfused rat hearts under normoxic and hypoxic conditions. RESULTS: Monte Carlo simulations showed NLSA to be superior to SA in identifying and quantifying the presence of irreversible trapping component (αo), for low values of αo. The performance of NLSA and SA for high values of trapping was comparable. NLSA was also more precise than SA in determining the absence of trapping over the range of simulated kinetics and SNR. Simulations also suggest that the semi-quantitative method NA is adequate for the evaluation of trapping, and it was found to be more accurate than Patlak. The values of α0 estimated with NLSA from the time series of both [18 F]-FDG and [18 F]-FMISO increased significantly from normoxia to hypoxia in agreement with previous studies. The values of trapping derived using SA increased but not significantly, reflecting the larger error associate with this method. Patlak estimated from the experimental datasets increased from normoxia to hypoxia but was not significant. NA estimated from the [18 F]-FDG data increased from normoxia to hypoxia, but was not significant, whilst NA calculated for [18 F]-FMISO time-activity curves increased significantly. CONCLUSIONS: Monte Carlo simulations suggested that spectral-based quantitative analysis methods are adequate for the kinetic characterisation of time-activity curves acquired ex vivo from perfused hearts. The uptake rate Patlak and the index NA also represent a good alternative to the SA and NLSA algorithms when the aim of the kinetic analysis is to measure changes in the amount of tracer trapped in the irreversible compartment in response to external stimuli. For low levels of trapping, NLSA and NA were subject to lower errors than SA and Patlak, respectively.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。