Accuracy, Clinical Utility, and Usability of a Wireless Self-Guided Fetal Heart Rate Monitor

无线自助式胎心监护仪的准确性、临床实用性和易用性

阅读:2

Abstract

OBJECTIVE: To evaluate the accuracy, clinical utility, and usability of a wireless fetal and maternal heartbeat monitor to monitor fetal heart rate (FHR). METHODS: We conducted a prospective, single-center study of a convenience sample of women aged 18 years or older with a singleton pregnancy of at least 12 weeks of gestation. Fetal heart rate recordings were performed using both the heartbeat monitor and cardiotocography to evaluate accuracy. Clinicians used the heartbeat monitor in the clinic. Women used the device, unassisted, during a clinic visit or at home. Obstetricians assessed the clinical utility of FHR traces. Women rated the heartbeat monitor using the System Usability Scale. RESULTS: A total of 81 participants provided 126 recordings. The accuracy of the heartbeat monitor was excellent compared with cardiotocography, with limits of agreement (95%) for mean FHR between -1.6 (CI -2.0 to 1.3) and +1.0 (CI 0.7-1.4) beats per minute (bpm), mean difference -0.3 bpm, intraclass coefficient 0.99. The FHR was detected on all occasions. Clinicians took a median (interquartile range) of 0.5 (0.2-1.2) minutes to detect the FHR, obtaining a continuous trace of longer than 1 minute in 95% (39/41) of occasions. Home users took a median of 0.5 (0.2-2.0) minutes to detect the FHR, obtaining a continuous trace of longer than 1 minute in 92% (24/26) of occasions, with a median total trace time of 4.6 (4.4-4.8) minutes. The traces were deemed clinically useful in 100% (55/55) of clinician and 97% (31/32) of home recordings. The heartbeat monitor ranked in the 96-100th percentile for usability and learnability. CONCLUSION: The heartbeat monitor was accurate and easy for clinicians and participants to use. Data recorded at home were equivalent to those obtained using current assessment protocols for low-risk pregnancies, potentially allowing the device to be used in telehealth consultations. CLINICAL TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry, ACTRN12620000739910. FUNDING SOURCES: The HeraBEAT devices used in this study were loaned by HeraMED Pty Ltd (HeraMED, Netanya, ISRAEL). The study was supported by PHI Research Group (not-for-profit), which was responsible for Statistician fees and Research Assistants' salaries. Joondalup Health Campus provided infrastructure support, and IT services in-kind to the PHI research group.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。