Novel high-throughput assay to assess cellular manganese levels in a striatal cell line model of Huntington's disease confirms a deficit in manganese accumulation

采用新型高通量检测方法评估亨廷顿氏病纹状体细胞系模型中的细胞锰水平,证实存在锰积累缺陷

阅读:7
作者:Gunnar F Kwakye, Daphne Li, Aaron B Bowman

Abstract

In spite of the essentiality of manganese (Mn) as a trace element necessary for a variety of physiological processes, Mn in excess accumulates in the brain and has been associated with dysfunction and degeneration of the basal ganglia. Despite the high sensitivity, limited chemical interference, and multi-elemental advantages of traditional methods for measuring Mn levels, they lack the feasibility to assess Mn transport dynamics in a high-throughput manner. Our lab has previously reported decreased net Mn accumulation in a mutant striatal cell line model of Huntington's disease (STHdh(Q111/Q111)) relative to wild-type following Mn exposure. To evaluate Mn transport dynamics in these striatal cell lines, we have developed a high-throughput fluorescence-quenching extraction assay (Cellular Fura-2 Manganese Extraction Assay - CFMEA). CFMEA utilizes changes in fura-2 fluorescence upon excitation at 360 nm (Ca(2+) isosbestic point) and emission at 535 nm, as an indirect measurement of total cellular Mn content. Here, we report the establishment, development, and application of CFMEA. Specifically, we evaluate critical extraction and assay conditions (e.g. extraction buffer, temperature, and fura-2 concentration) required for efficient extraction and quantitative detection of cellular Mn from cultured cells. Mn concentrations can be derived from quenching of fura-2 fluorescence with standard curves based on saturation one-site specific binding kinetics. Importantly, we show that extracted calcium and magnesium concentrations below 10 μM have negligible influence on measurements of Mn by fura-2. CFMEA is able to accurately measure extracted Mn levels from cultured striatal cells over a range of at least 0.1-10 μM. We have used two independent Mn supplementation approaches to validate the quantitative accuracy of CFMEA over a 0-200 μM cellular Mn-exposure range. Finally, we have utilized CFMEA to experimentally confirm a deficit in net Mn accumulation in the mutant HD striatal cell line versus wild-type cells. To conclude, we have developed and applied a novel assay to assess Mn transport dynamics in cultured striatal cell lines. CFMEA provides a rapid means of evaluating Mn transport kinetics in cellular toxicity and disease models.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。