Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes

下颌覆盖义齿由1或2个种植体固位:一项为期5年的随机临床试验,研究种植体稳定性及种植体周围组织结果

阅读:2

Abstract

AIM: This is a report of the 5-year results of a two-group parallel randomized clinical trial comparing longitudinal implant stability, and clinical and radiographic peri-implant outcomes of mandibular overdentures retained by one (1-IOD group) or two (2-IOD group) implants. METHODS: All participants received 4.1 mm diameter tissue-level implants (Straumann(®) Standard Plus - SLActive(®), Institut Straumann AG), installed in the mandible midline (1-IOD; n = 23) or the lateral incisor-canine area bilaterally (2-IOD; n = 24), and loaded after 3 weeks. Implant Stability Quotient (ISQ) was measured using a resonance frequency device (Osstell(®) Mentor, Integration Diagnostics) at implant placement, after three weeks (loading), and at the 6-month, 1-, 3-, and 5-year follow-ups. Marginal bone loss and clinical implant outcomes (plaque, calculus, suppuration and bleeding) were assessed periodically up to 5 years after loading. RESULTS: Only minor changes in marginal bone level were observed after 5 years (mean = 0.37; SD = 0.44 mm), and satisfactory and stable peri-implant parameters were observed throughout the 5-year follow-up. No significant differences between groups were found. Overall, the mean primary implant stability was considered high (> 70) for the two groups (1-IOD = 78.1 ± 4.5; 2-IOD = 78.0 ± 5.8). No noticeable changes were observed between implant insertion and loading. A marked increase was observed from insertion to the 6-month follow-up - the mean difference for the 1-IOD group was + 5.5 ± 5.5 (Effect size = 1.00), while for the 2-IOD group, the mean difference was + 6.0 ± 5.6 (Effect size = 1.08). No relevant changes were observed throughout the follow-up periods up to 5 years. Linear mixed-effect model regression showed no influence of the bone-related variables (p > 0.05) and the number of implants (p = 0.087), and a significant effect of the time variable (p < 0.001). CONCLUSION: Satisfactory peri-implant outcomes and stable secondary stability suggest good clinical performance and successful long-term osseointegration of the implants for single and two-implant mandibular overdentures. Using a single implant to retain a mandibular overdenture does not seem to result in detrimental implant loading over the five years of overdenture use. CLINICAL RELEVANCE: This study corroborates the use of a single implant to retain a mandibular denture.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。