Recombinant adenovirus as a model to evaluate the efficiency of free chlorine disinfection in filtered water samples

以重组腺病毒为模型评价过滤水样中游离氯消毒的效率

阅读:14
作者:Mariana A Nascimento, Maria E Magri, Camila D Schissi, Célia Rm Barardi

Background

In Brazil, ordinance no. 2,914/2011 of the Ministry of Health requires the absence of total coliforms and Escherichia coli (E. coli) in treated water. However it is essential that water treatment is effective against all pathogens. Disinfection in Water Treatment Plants (WTP) is commonly performed with chlorine.

Conclusion

The Chick-Watson model proved to have adjusted well to the experimental conditions used, and it was possible to prove that the adenoviruses were rapidly inactivated in the surface water treated with chlorine and that the recombinant adenovirus expressing GFP is a good model for this evaluation.

Methods

The recombinant adenovirus (rAdV), which expresses green fluorescent protein (GFP) when cultivated in HEK 293A cells, was chosen as a model to evaluate the efficiency of chlorine for human adenovirus (HAdV) inactivation in filtered water samples from two WTPs: Lagoa do Peri (pH 6.9) and Morro dos Quadros (pH 6.5). Buffered demand free (BDF) water (pH 6.9 and 8.0) was used as control. The samples were previously submitted to physicochemical characterization, and bacteriological analysis. Two free chlorine concentrations and two temperatures were assayed for all samples (0.2 mg/L, 0.5 mg/L, and 15°C, and 20°C). Fluorescence microscopy (FM) was used to check viral infectivity in vitro and qPCR as a molecular method to determine viral genome copies. Real treated water samples from the WTP (at the output of WTP and the distribution network) were also evaluated for total coliforms, E. coli and HAdV.

Results

The time required to inactivate 4log&sub1;&sub0; of rAdV was less than 1 min, when analyzed by FM, except for BDF pH 8.0 (up to 2.5 min for 4log&sub1;&sub0;). The pH had a significant influence on the efficiency of disinfection. The qPCR assay was not able to provide information regarding rAdV inactivation. The data were modeled (Chick-Watson), and the observed Ct values were comparable with the values reported in the literature and smaller than the values recommended by the EPA. In the treated water samples, HAdV was detected in the distribution network of the WTP Morro dos Quadros (2.75 × 10(3) PFU/L).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。