Correlation of oxygenation indices in invasive mechanical ventilated adult patients

有创机械通气成人患者氧合指标的相关性

阅读:1

Abstract

BACKGROUND: Mechanical ventilation is essential for managing acute respiratory failure, but traditional methods of assessing oxygenation, like the PaO2/FiO2 ratio, pose challenges due to invasiveness and cost. OBJECTIVE: This single-centre prospective observational study aimed to assess the potential of the non-invasive Oxygen Saturation Index (OSI), utilising SpO2 measurements, to diagnose hypoxemia in mechanically ventilated adults. The study sought to establish correlations between OSI, oxygenation index (OI), PaO2/FiO2 ratio and SpO2/FiO2 ratio. METHODS: From August 2022 to July 2023, data was collected from 1055 mechanically ventilated intensive care unit patients. Statistical analysis included correlation tests, receiver operating curve (ROC) analysis and cut-off value determination for hypoxemia diagnosis. RESULTS: We found that the P/F ratio had a statistically significant negative correlation with OI (correlation coefficient -0.832, P value: 0.000 in hypoxemic group and correlation coefficient -0.888, P value: 0.000 in the non-hypoxemic group), and OSI (correlation coefficient -0.746, P value: 0.000 in hypoxemic group and correlation coefficient -0.629, P value: 0.000 in non-hypoxemic group) and has a positive correlation with P/F ratio (correlation coefficient 0.92, P value: 0.000 in hypoxemic group and correlation coefficient -0.67, P value: 0.000 in non-hypoxemic group). OI and OSI had a statistically significant correlation (correlation coefficient 0.955, P value: 0.000 in hypoxemic group and correlation coefficient 0.815, P value: 0.000 in non-hypoxemic group). on ROC analysis P/F ratio was the most accurate in predicting hypoxia followed by OI and OSI. with a cut-off value, of OI being 7.07, and that for OSI being 3.90, at an 80% sensitivity level to diagnose hypoxemia. CONCLUSION: OSI can serve as a dependable surrogate for OI, simplifying ARDS severity assessment. The P/F ratio is the most accurate predictor of hypoxia. Further research, especially in larger multicentre studies, is needed to validate these findings and explore the long-term clinical implications of using OSI for oxygenation monitoring in mechanically ventilated patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。