Accuracy of endobronchial ultrasound (EBUS) in the staging of lung cancer - A comparison of staging EBUS with postoperative pathological nodal staging

支气管内超声(EBUS)在肺癌分期中的准确性——EBUS分期与术后病理淋巴结分期的比较

阅读:1

Abstract

BACKGROUND: Endobronchial ultrasound-guided transbronchial fine-needle aspiration (EBUS-TBNA) has replaced mediastinoscopy as the preferred investigation for evaluating mediastinum in staging lung cancer. There is little evidence of mediastinal staging by EBUS-TBNA from India. OBJECTIVES: To study endobronchial ultrasound's diagnostic accuracy in staging lung cancer. METHODOLOGY: We retrospectively analysed patients operated on for lung cancer where EBUS was performed preoperatively for mediastinal staging. We compared the histological findings obtained from different mediastinal lymph nodes (LNs) by EBUS-TBNA with the pathology of the same LNs obtained after surgical dissection as the reference standard. RESULTS: Seventy-six patients underwent curative surgery for lung cancer. The diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of EBUS-TBNA in predicting mediastinal metastasis were 93.9%, 40%, 99%, 80% and 94.6%, respectively. Of the 115 LNs sampled, EBUS-TBNA was false negative in six nodes, resulting in an up-staging of six patients. CONCLUSIONS: EBUS-TBNA has a high diagnostic accuracy for lung cancer staging.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。