Abstract
OBJECTIVE: To determine the relationship between hearing loss etiology, cochlear implant (CI) programming levels, and speech perception performance in a large clinical cohort of pediatric CI recipients. STUDY DESIGN: Retrospective chart review. SETTING: Tertiary care hospitals. PATIENTS: A total of 136 pediatric CI recipients (218 ears) were included in this study. All patients had diagnoses of either enlarged vestibular aqueduct (EVA) or GJB2 (Connexin-26) mutation confirmed via radiographic data and/or genetic reports. All patients received audiologic care at either Boston Children's Hospital or Massachusetts Eye and Ear in Boston, MA, between the years 1999 and 2020. MAIN OUTCOME MEASURES: Electrode impedances and programming levels for each active electrode and speech perception scores were evaluated as a function of etiology (EVA or GJB2 mutation). RESULTS: Children with EVA had significantly higher impedances and programming levels (thresholds and upper stimulation levels) than the children with GJB2 mutation. Speech perception scores did not differ as a function of etiology in this sample; rather, they were positively correlated with duration of CI experience (time since implantation). CONCLUSIONS: Differences in electrode impedances and CI programming levels suggest that the electrode-neuron interface varies systematically as a function of hearing loss etiology in pediatric CI recipients with EVA and those with GJB2 mutation. Time with the CI was a better predictor of speech perception scores than etiology, suggesting that children can adapt to CI stimulation with experience.