Electrode Location and Angular Insertion Depth Are Predictors of Audiologic Outcomes in Cochlear Implantation

电极位置和插入角度深度是人工耳蜗植入术后听力学结果的预测因素

阅读:1

Abstract

OBJECTIVES: 1) Investigate the impact of electrode type and surgical approach on scalar electrode location; and 2) examine the relation between electrode location and postoperative audiologic performance. SETTING: Tertiary academic hospital. PATIENTS: Two hundred twenty post-lingually deafened adults undergoing cochlear implant (CI). MAIN OUTCOME MEASURES: Primary outcome measures of interest were scalar electrode location and postoperative audiologic performance. RESULTS: In 68% of implants, electrodes were observed to be located solely in the scala tympani (ST). Multivariate analysis demonstrated perimodiolar (PM) and mid-scala (MS) electrodes were 22.4 (95% CI: 6.3-80.0, p < 0.001) and 55.0 (95% CI: 9.7-312.8, p < 0.001) times more likely to have at least one electrode in the scala vestibuli (SV) compared with lateral wall (LW) electrodes, respectively. Compared with cochleostomy (C), round window (RW) and extended round window (ERW) approaches demonstrated 70% reduction in SV insertion (RW: OR 0.28, 95% CI: 0.1-0.8, p = 0.01; ERW: OR 0.28, 95% CI: 0.1-0.7, p = 0.005). Examining postoperative audiometric performance, consonant-nucleus-consonant (CNC) score increased 0.6% with every 10 degrees increase in angular insertion depth beyond the group minimum of 208 degrees (coefficient 0.0006, 95% CI: 0.0001-0.001, p = 0.03). SV insertion was associated with a 12% decrease in CNC score (coefficient -0.12, 95% CI: -0.22 to -0.02, p = 0.02). CNC score decreased 0.3% for every 1 year increase in age (coefficient -0.003, 95% CI: -0.006 to -0.0006, p = 0.02). CONCLUSIONS: Electrode design and surgical approach were predictors of scalar electrode location. Specifically, LW electrodes showed higher rates of ST insertion compared with PM or MS. RW and ERW approaches showed higher rates of ST insertion when compared with C. In regards to performance, ST insertion, younger age, and greater angular insertion depth were predictors of improved CNC scores.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。