Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report

采用8字形不锈钢丝修复10只猫远端股骨骨骺骨折:病例报告

阅读:1

Abstract

Ten cats were treated for distal femoral Salter-Harris fractures types I and II using a stainless steel wire in a figure-of-eight configuration. Healing was uneventful in 8 of the cats. Early fixation failure occurred in one cat, which required revisional surgery. In one cat, lameness recurred after fracture healing, which was related to breakage of the wire. The lameness was resolved after removing the wire. At the long-term follow-up, 1 out of 6 cats was lame. This report indicates that the figure-of-eight stainless steel wire technique is an alternative method for the repair of distal femoral Salter-Harris fractures types I and II in cats.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。