Hypokalaemia and sudden cardiac death--lessons from implantable cardioverter defibrillators

低钾血症和猝死——植入式心脏复律除颤器的教训

阅读:1

Abstract

The cases of four patients experiencing ventricular arrhythmia secondary to drug-induced hypokalaemia requiring treatment by a previously implanted cardioverter defibrillator (ICD) are reported here. In three cases, hypokalaemia developed within a short period of time after modification of diuretic regimen with loop and thiazide diuretics had been carried out or potassium-sparing drugs had been withdrawn. In one patient, hypokalaemia occurred after months of treatment with several potassium-sparing and non-potassium-sparing diuretics. The fact that the combination of thiazide and loop diuretics can be associated with pronounced hypokalaemia and life-threatening arrhythmias, which may be terminated by device treatment in patients with an ICD but may be fatal in patients with structural heart disease but without an ICD, is highlighted here. Prompt recognition and correction of hypokalaemia is mandatory if such patients present to the emergency department.