Investigating pulmonary embolism in the emergency department with lower limb plethysmography: the Manchester Investigation of Pulmonary Embolism Diagnosis (MIOPED) study

在急诊科应用下肢容积描记法检查肺栓塞:曼彻斯特肺栓塞诊断研究(MIOPED)

阅读:2

Abstract

OBJECTIVES: To measure the diagnostic accuracy of computerised strain gauge plethysmography in the diagnosis of pulmonary embolism (PE). METHODS: Two researchers prospectively recruited 425 patients with pleuritic chest pain presenting to the emergency department (ED). Lower limb computerised strain gauge plethysmography was performed in the ED. All patients underwent an independent reference standard diagnostic algorithm to establish the presence or absence of PE. A low modified Wells' clinical probability combined with a normal D-dimer excluded PE. All others required diagnostic imaging with PIOPED interpreted ventilation perfusion scanning and/or computerised tomography (CT) pulmonary angiography. Patients with a nondiagnostic CT had digital subtraction pulmonary angiography. All patients were followed up clinically for 3 months. RESULTS: The sensitivity of computerised strain gauge plethysmography was 33.3% (95% confidence interval (CI) 16.3 to 56.2%) and specificity 64.1% (95% CI 59.0 to 68.8%). The negative likelihood ratio was 1.04 (95% CI 0.68 to 1.33) and positive likelihood ratio 0.93 (95% CI 0.45 to 1.60). CONCLUSIONS: Lower limb computerised strain gauge plethysmography does not aid in the diagnosis of PE.