Indirect Flow Diversion for Off-Centered Bifurcation Aneurysms and Distant Small-Vessel Aneurysms, a Retrospective Proof of Concept Study From Five Neurovascular Centers

针对偏心分叉动脉瘤和远端小血管动脉瘤的间接血流导向治疗:来自五个神经血管中心的回顾性概念验证研究

阅读:1

Abstract

Background: Treatment of cerebral aneurysms using hemodynamic implants such as endosaccular flow disruptors and endoluminal flow diverters has gained significant momentum during recent years. The intended target zone of those devices is the immediate interface between aneurysm and parent vessel. The therapeutic success is based on the reduction of aneurysmal perfusion and the subsequent formation of a neointima along the surface of the implant. However, a subset of aneurysms-off-centered bifurcation aneurysms involving the origin of efferent branches and aneurysms arising from peripheral segments of small cerebral vessels-oftentimes cannot be treated via coiling or implanting a hemodynamic implant at the neck level for technical reasons. In those cases, indirect flow diversion-a flow diverter deployed in the main artery proximal to the parent vessel of the aneurysm-can be a viable treatment strategy, but clinical evidence is lacking in this regard. Materials and Methods: Five neurovascular centers contributed to this retrospective analysis of patients who were treated with indirect flow diversion. Clinical data, aneurysm characteristics, anti-platelet medication, and follow-up results, including procedural and post-procedural complications, were recorded. Results: Seventeen patients (mean age: 60.5 years, range: 35-77 years) with 17 target aneurysms (vertebrobasilar: n = 9) were treated with indirect flow diversion. The average distance between the flow-diverting stent and the aneurysm was 1.65 mm (range: 0.4-2.4 mm). In 15/17 patients (88.2%), perfusion of the aneurysm was reduced immediately after implantation. Follow-ups were available for 12 cases. Delayed opacification (OKM A3: 11.8%), reduction in size (OKM B1-3: 29.4%) and occlusion (D1: 47.1%) were observable at the latest investigation. Clinically relevant procedural complications and adverse events in the early phase and in the late subacute phase were not observed in any case. Conclusion: Our preliminary data suggest that indirect flow diversion is a safe, feasible, and effective approach to off-centered bifurcation aneurysms and distant small-vessel aneurysms. However, validation with larger studies, including long-term outcomes and optimized imaging, is warranted.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。