Evaluation of optic nerve sheath diameter in patients undergoing laparoscopic surgery in the Trendelenburg position: a prospective observational study

评估采用头低脚高位行腹腔镜手术患者视神经鞘直径:一项前瞻性观察研究

阅读:1

Abstract

BACKGROUND: The Trendelenburg position and pneumoperitoneum may cause cerebral edema and increased intracranial pressure. Non-invasive measurement of the diameter of the optic nerve sheath by ultrasonography can provide early recognition of intracranial pressure. OBJECTIVE: Evaluate the optic nerve sheath diameter (ONSD) changes in patients who undergo laparoscopic surgery in the Trendelenburg position and make indirect conclusions about changes in intracranial pressure. DESIGN: Prospective, observational. SETTING: Laparoscopic surgeries. PATIENTS AND METHODS: Patients aged 18-75 years who underwent laparoscopic surgery in the Trendelenburg position under general anesthesia were included in our study. The ONSD was measured four times: Immediately after tracheal intubation, in the neutral position (baseline value) (T0), 10 minutes after pneumoperitoneum and Trendelenburg position (T1), 60 minutes after pneumoperitoneum and Trendelenburg position (T2), and 10 minutes after the pneumoperitoneum is terminated and placed in the neutral position (T3). MAIN OUTCOME MEASURES: Compare ONSD measured by ultrasonography at different times of surgery. SAMPLE SIZE: 40. RESULTS: Arterial carbon dioxide pressure increased with laparoscopy and Trendelenburg position in parallel with ONSD measurements and decreased again after returning to the neutral position. It was still higher than the baseline value at the T3. There was also a significant difference[a] between the measurement made at the T2 and the measurement made at T1. This difference showed that the prolongation of the Trendelenburg time was associated with an increase in ONSD. At the end of the operation it was observed that the decreased statistically significantly (T3) 10 minutes after the pneumoperitoneum was terminated and the position was corrected. However, the ONSD was still higher at the end of the operation (T3) compared to the baseline value measured at the beginning of the operation (T0). CONCLUSION: The ONSD increased in relation to Trendelenburg position and pneumoperitoneum. With these results, we think the ultrasonographic measurement of ONSD, a non-invasive method, can be used for clinical follow-up when performing laparoscopic surgery in the Trendelenburg position in cases requiring intracranial pressure monitoring. LIMITATIONS: There may be variations in the measurement of ONSD, even in the measurements of the same practitioner, as in all imaging with an ultrasonography device.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。