Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: A Randomized Clinical Trial

采用26号惠特克针和0.125%布比卡因推注进行硬膜穿刺硬膜外麻醉与传统硬膜外麻醉在分娩镇痛起效方面的比较:一项随机临床试验

阅读:1

Abstract

BACKGROUND: Lumbar epidurals (LEs) provide excellent analgesia. Combined spinal epidural and dural puncture epidural (DPE) are 2 techniques to expedite neuraxial analgesia onset. In DPE, dura is punctured but medication is not administered in the cerebrospinal fluid. Expedited analgesia onset has been demonstrated with DPE, using 0.25% bupivacaine; however, this concentration may impede an unassisted vaginal birth and is not currently used for induction and maintenance of labor analgesia. The primary goal of this study was to compare the percentage of patients who achieved adequate labor analgesia following DPE or LE with an epidural bolus of 0.125% bupivacaine. Adequate labor analgesia was defined as Visual Analog Scale (VAS) measurement ≤ 10 mm on a 100-mm scale during active contractions, measured 10 minutes after epidural bolus initiation. METHODS: Laboring patients were randomly assigned to receive LE or DPE. Immediately before epidural placement, subjects marked a VAS score during an active contraction and parturients with VAS < 50 mm were excluded. The epidural space was identified by a loss of resistance technique to saline (17G Tuohy needle [Arrow International, Inc, Redding, PA]). In the DPE group, dura was punctured with a 26G Whitacre needle (Arrow International, Inc). In all participants, a 19G epidural catheter (Arrow International, Inc) was inserted. An epidural bolus was then administered over 3 minutes (12 mL, 0.125% bupivacaine, 50 μg fentanyl) followed by infusion (0.1% bupivacaine, 2 μg/mL fentanyl). After initiation of epidural bolus (time zero), VAS measurements were collected at 2-minute intervals for up to 20 minutes. Median time to achieve adequate analgesia by treatment group was assessed by Kaplan-Meier analysis. Time to achieving adequate analgesia was evaluated using a Cox regression model. All analyses were conducted in SAS version 9.4. (SAS Institute, Cary, NC) RESULTS:: Data were analyzed from 80 participants (40 per group). Adequate analgesia at 10 minutes did not differ by neuraxial technique (DPE = 55.3% vs LE = 44.7%; P= .256). However, parturients receiving DPE had shorter median times to adequate analgesia (median [95% confidence interval], 8 minutes [6-10] vs 10 minutes [8-14]) and a 67% increase in the relative risk of achieving adequate analgesia compared to LE (relative risk = 1.67; 95% confidence interval, 1.02-2.64; P= .042). CONCLUSIONS: Although the percentage of parturients achieving adequate labor analgesia at 10 minutes after epidural bolus did not differ by technique, DPE was associated with faster time to VAS ≤ 10 mm compared with LE.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。