Management of 1-Lung Ventilation-Variation and Trends in Clinical Practice: A Report From the Multicenter Perioperative Outcomes Group

单肺通气管理——临床实践中的变异和趋势:来自多中心围手术期结局组的报告

阅读:1

Abstract

BACKGROUND: Lung-protective ventilation (LPV) has been demonstrated to improve clinical outcomes in surgical patients. There are very limited data on the current use of LPV for patients undergoing 1-lung ventilation (1LV) despite evidence that 1LV may be a particularly important setting for its use. In this multicenter study, we report trends in ventilation practice for patients undergoing 1LV. METHODS: The Multicenter Perioperative Outcomes Group database was used to identify patients undergoing 1LV. We retrieved and calculated median initial and overall tidal volume (VT) for the cohort and for high-risk subgroups (female sex, obesity [body mass index >30 kg/m], and short stature), percentage of patients receiving positive end-expiratory pressure (PEEP) ≥5 cm H2O, LPV during 1LV (VT ≤ 6 mL/kg predicted body weight [PBW] and PEEP ≥5 cm H2O), and ventilator driving pressure (ΔP; plateau airway pressure - PEEP). RESULTS: Data from 5609 patients across 4 institutions were included in the analysis. Median VT was calculated for each case and since the data were normally distributed, the mean is reported for the entire cohort and subgroups. Mean of median VT during 1LV for the cohort was 6.49 ± 1.82 mL/kg PBW. VT (mL/kg PBW) for high-risk subgroups was significantly higher; 6.86 ± 1.97 for body mass index ≥30 kg/m, 7.05 ± 1.92 for female patients, and 7.33 ± 2.01 for short stature patients. Mean of the median VT declined significantly over the study period (from 6.88 to 5.72; P < .001), and the proportion of patients receiving LPV increased significantly over the study period (from 9.1% to 54.6%; P < .001). These changes coincided with a significant decrease in ΔP during the study period, from 19.4 cm H2O during period 1 to 17.3 cm H2O in period 12 (P = .003). CONCLUSIONS: Despite a growing awareness of the importance of protective ventilation, a large proportion of patients undergoing 1LV continue to receive VT PEEP levels outside of recommended thresholds. Moreover, VT remains higher and LPV less common in high-risk subgroups, potentially placing them at elevated risk for iatrogenic lung injury.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。