Stationary versus agitated storage of whole blood during acute normovolemic hemodilution

急性等容血液稀释过程中全血的静置储存与振荡储存的比较

阅读:1

Abstract

BACKGROUND: Acute normovolemic hemodilution is an intraoperative technique to reduce the number of red blood cells lost in shed blood during surgery. Standard guidelines for storage of platelets recommend constant gentle agitation to maintain gas exchange for the metabolically active platelets. The collected whole blood (WB) for acute normovolemic hemodilution remains stationary for as long as 8 hours before reinfusion. We hypothesized that gentle agitation of WB throughout storage would improve the coagulation properties of the WB at the time of reinfusion. METHODS: WB was collected from 10 volunteer donors and control samples taken. The units were split in 2 storage groups: agitated (rocked) and stationary (unrocked). Cell counts and fibrinogen levels, as well as thromboelastography (TEG®) measurements, including TEG® PlateletMapping® assays, were performed on the control sample and the test samples after 8 hours of rocked or unrocked storage at room temperature. RESULTS: Nine units WB from 9 different healthy volunteers were tested. There were no significant differences in hematocrit, hemoglobin, red blood cells counts, platelet counts, or fibrinogen levels between the control samples and the rocked and unrocked WB samples. WB coagulation as measured by TEG® was preserved during the 8-hour storage period in both the rocked and unrocked samples. There were no significant differences between the control, rocked, and unrocked samples in time to initiate clotting, time of clot formation, rate of clot formation, or maximum strength of clot values. There were also no significant differences in the fibrin contribution to clot strength between the control, rocked, and unrocked samples, and no significant difference between the platelet activation from adenosine diphosphate or arachidonic acid among any of the 3 groups. CONCLUSIONS: Given the small sample size, there is no statistical evidence on which to reject the null hypothesis of there being no difference in the changes from the baseline between coagulation function as measured by TEG® between WB that is either agitated or kept stationary for 8 hours. These findings need to be confirmed in a larger study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。