Dosage uniformity problems which occur due to technological errors in extemporaneously prepared suppositories in hospitals and pharmacies

医院和药房临时配制栓剂时,由于技术错误而导致的剂量均匀性问题

阅读:2

Abstract

The availability of suppositories in Hungary, especially in clinical pharmacy practice, is usually provided by extemporaneous preparations. Due to the known advantages of rectal drug administration, its benefits are frequently utilized in pediatrics. However, errors during the extemporaneous manufacturing process can lead to non-homogenous drug distribution within the dosage units. To determine the root cause of these errors and provide corrective actions, we studied suppository samples prepared with exactly known errors using both cerimetric titration and HPLC technique. Our results show that the most frequent technological error occurs when the pharmacist fails to use the correct displacement factor in the calculations which could lead to a 4.6% increase/decrease in the assay in individual dosage units. The second most important source of error can occur when the molding excess is calculated solely for the suppository base. This can further dilute the final suppository drug concentration causing the assay to be as low as 80%. As a conclusion we emphasize that the application of predetermined displacement factors in calculations for the formulation of suppositories is highly important, which enables the pharmacist to produce a final product containing exactly the determined dose of an active substance despite the different densities of the components.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。