Comparison of SureSelect and Nextera Exome Capture Performance in Single-Cell Sequencing

SureSelect 和 Nextera 外显子组捕获技术在单细胞测序中的性能比较

阅读:1

Abstract

BACKGROUND: Advances in single-cell sequencing provide unprecedented opportunities for clinical examination of circulating tumor cells, cancer stem cells, and other rare cells responsible for disease progression and drug resistance. On the genomic level, single-cell whole exome sequencing (scWES) started to gain popularity with its unique potentials in characterizing mutational landscapes at a single-cell level. Currently, there is little known about the performance of different exome capture kits in scWES. Nextera rapid capture (NXT; Illumina, Inc.) has been the only exome capture kit recommended for scWES by Fluidigm C1, a widely accessed system in single-cell preparation. RESULTS: In this study, we compared the performance of NXT following Fluidigm's protocol with Agilent SureSelectXT Target Enrichment System (AGL), another exome capture kit widely used for bulk sequencing. We created DNA libraries of 192 single cells isolated from spheres grown from a melanoma specimen using Fluidigm C1. Twelve high-yield cells were selected to perform dual-exome capture and sequencing using AGL and NXT in parallel. After mapping and coverage analysis, AGL outperformed NXT in coverage uniformity, mapping rates of reads, exome capture rates, and low PCR duplicate rates. For germline variant calling, AGL achieved better performance in overlap with known variants in dbSNP and transition-transversion ratios. Using calls from high coverage bulk sequencing from blood DNA as the golden standard, AGL-based scWES demonstrated high positive predictive values, and medium to high sensitivity. Lastly, we evaluated somatic mutation calling by comparing single-cell data with the matched blood sequence as control. On average, 300 mutations were identified in each cell. In 10 of 12 cells, higher numbers of mutations were identified using AGL than NXT, probably caused by coverage depth. When mutations are adequately covered in both AGL and NXT data, the two methods showed very high concordance (93-100% per cell). CONCLUSIONS: Our results suggest that AGL can also be used for scWES when there is sufficient DNA, and it yields better data quality than the current Fluidigm's protocol using NXT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。