Test-Retest Reliability of Single-Arm Closed Kinetic Chain Upper Extremity Stability Test

单臂闭链上肢稳定性测试的重测信度

阅读:1

Abstract

Background: The original Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) is a simple assessment tool but does not account for individual differences in hand starting position and fails to provide information on limb asymmetries. The purpose of the study is to evaluate the test-retest reliability of a new single-arm CKCUEST as well as the reliability of the limb symmetry index (LSI). This version normalizes the test based on the participant's arm length and allows for the assessment of limb symmetry since it is performed one arm at a time. Methods: Twelve healthy young adults provided both verbal and written consent to participate. Participants were excluded if they had sustained an injury in the past three months requiring medical attention and/or resulting in decreased activity for more than three days. Testing was conducted in the push-up position with participants' thumbs placed parallel and at a distance equal to the length of their dominant arm (measured from the acromion to the tip of the middle finger), and feet positioned shoulder-width apart. Participants were instructed to keep the testing hand stable on the floor while the opposite hand reached across the body to touch the stationary hand and then return to the starting position marked with athletic tape. The goal was to complete as many touches as possible in 15 s, with each touch counted only if the participant touched the stationary hand, returned to the starting position, and maintained the shoulder-width stance. The average number of touches from the three trials was used for analysis. Intraclass Correlation Coefficients (ICC((3,1))) were computed to determine test-retest reliability. Results: Test-retest reliability of the single-arm CKCUEST individual tests was good to excellent. The ICC((3,1)) was 0.88 (95% CI: 0.74-0.95) for all tests, 0.89 (95% CI: 0.66-0.96) for the dominant arm, and 0.93 (95% CI: 0.78-0.98) for the non-dominant arm. In contrast, the reliability of the Limb Symmetry Index (LSI) was questionable, showing substantial variability with an ICC((3,1)) of 0.53 (95% CI: -0.03-0.83) between Day 1 and Day 2, despite similar mean values (Day 1: 93.6 ± 8.46; Day 2: 94.8 ± 5.77). The Kappa coefficient suggested a substantial level of agreement for the direction of the asymmetry (preferred limb) (Kappa coefficient = 0.62). Conclusions: The new single-arm CKCUEST, which personalizes the hand starting position and measures limb symmetry, demonstrates high reliability among healthy young adults.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。