Improving reproducibility and performance of radiomics in low-dose CT using cycle GANs

利用循环生成对抗网络提高低剂量CT放射组学的可重复性和性能

阅读:1

Abstract

BACKGROUND: As a means to extract biomarkers from medical imaging, radiomics has attracted increased attention from researchers. However, reproducibility and performance of radiomics in low-dose CT scans are still poor, mostly due to noise. Deep learning generative models can be used to denoise these images and in turn improve radiomics' reproducibility and performance. However, most generative models are trained on paired data, which can be difficult or impossible to collect. PURPOSE: In this article, we investigate the possibility of denoising low-dose CTs using cycle generative adversarial networks (GANs) to improve radiomics reproducibility and performance based on unpaired datasets. METHODS AND MATERIALS: Two cycle GANs were trained: (1) from paired data, by simulating low-dose CTs (i.e., introducing noise) from high-dose CTs and (2) from unpaired real low dose CTs. To accelerate convergence, during GAN training, a slice-paired training strategy was introduced. The trained GANs were applied to three scenarios: (1) improving radiomics reproducibility in simulated low-dose CT images and (2) same-day repeat low dose CTs (RIDER dataset), and (3) improving radiomics performance in survival prediction. Cycle GAN results were compared with a conditional GAN (CGAN) and an encoder-decoder network (EDN) trained on simulated paired data. RESULTS: The cycle GAN trained on simulated data improved concordance correlation coefficients (CCC) of radiomic features from 0.87 (95%CI, [0.833,0.901]) to 0.93 (95%CI, [0.916,0.949]) on simulated noise CT and from 0.89 (95%CI, [0.881,0.914]) to 0.92 (95%CI, [0.908,0.937]) on the RIDER dataset, as well improving the area under the receiver operating characteristic curve (AUC) of survival prediction from 0.52 (95%CI, [0.511,0.538]) to 0.59 (95%CI, [0.578,0.602]). The cycle GAN trained on real data increased the CCCs of features in RIDER to 0.95 (95%CI, [0.933,0.961]) and the AUC of survival prediction to 0.58 (95%CI, [0.576,0.596]). CONCLUSION: The results show that cycle GANs trained on both simulated and real data can improve radiomics' reproducibility and performance in low-dose CT and achieve similar results compared to CGANs and EDNs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。