False-positive Xpert(®) Xpress SARS-CoV-2 assay in an emergency room and trauma center: A retrospective chart review study

急诊室和创伤中心 Xpert® Xpress SARS-CoV-2 检测假阳性:一项回顾性病历审查研究

阅读:1

Abstract

OBJECTIVES: To review reports false-positive Xpert results in an emergency room and trauma center. METHODS: Patients' data with false-positive Xpert results from November 2020 to February 2022 at Pusan National University Hospital, Busan, Republic of Korea, were extracted from the electronic medical records. RESULTS: The positive predictive value of Xpert was 40%. Of the 12 patients with false-positive results, 5 (41.7%) were re-positives (such as, patients recovered from coronavirus disease-19 [COVID-19]), and 4 (33.3%) had head or facial trauma. Two out of 4 head or facial trauma cases had documented sample contamination with blood. CONCLUSION: We found a high incidence of false-positive Xpert results among patients who recovered from COVID-19 and those with head or facial injury. Careful history taking for COVID-19 and physical examination of the sample collection site is essential before Xpert analysis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。