The Impact of Technology on Prescribing Errors in Pediatric Intensive Care: A Before and After Study

技术对儿科重症监护处方错误的影响:一项前后对比研究

阅读:1

Abstract

BACKGROUND: Increased use of health information technology (HIT) has been advocated as a medication error reduction strategy. Evidence of its benefits in the pediatric setting remains limited. In 2012, electronic prescribing (ICCA, Philips, United Kingdom) and standard concentration infusions (SCIs)-facilitated by smart-pump technology-were introduced into the pediatric intensive care unit (PICU) of an Irish tertiary-care pediatric hospital. OBJECTIVE: The aim of this study is to assess the impact of the new technology on the rate and severity of PICU prescribing errors and identify technology-generated errors. METHODS: A retrospective, before and after study design, was employed. Medication orders were reviewed over 24 weeks distributed across four time periods: preimplementation (Epoch 1); postimplementation of SCIs (Epoch 2); immediate postimplementation of electronic prescribing (Epoch 3); and 1 year postimplementation (Epoch 4). Only orders reviewed by a clinical pharmacist were included. Prespecified definitions, multidisciplinary consensus and validated grading methods were utilized. RESULTS: A total of 3,356 medication orders for 288 patients were included. Overall error rates were similar in Epoch 1 and 4 (10.2 vs. 9.8%; p = 0.8), but error types differed (p < 0.001). Incomplete and wrong unit errors were eradicated; duplicate orders increased. Dosing errors remained most common. A total of 27% of postimplementation errors were technology-generated. Implementation of SCIs alone was associated with significant reductions in infusion-related prescribing errors (29.0% [Epoch 1] to 14.6% [Epoch 2]; p < 0.001). Further reductions (8.4% [Epoch 4]) were identified after implementation of electronically generated infusion orders. Non-infusion error severity was unchanged (p = 0.13); fewer infusion errors reached the patient (p < 0.01). No errors causing harm were identified. CONCLUSION: The limitations of electronic prescribing in reducing overall prescribing errors in PICU have been demonstrated. The replacement of weight-based infusions with SCIs was associated with significant reductions in infusion prescribing errors. Technology-generated errors were common, highlighting the need for on-going research on HIT implementation in pediatric settings.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。