Abstract
PURPOSE: To explore the utility of eye tracking glasses in patients with intermittent exotropia as a means for quantifying the occurrence of exotropia, defined as the percentage of time that the eyes are misaligned. DESIGN: Prospective observational study. METHODS: Eye tracking glasses were used to obtain 68 recordings in 44 ambulatory patients with a history of intermittent exotropia. Vergence angle was monitored for up to 12 hours to document the occurrence of exotropia. RESULTS: Intermittent exotropia was present in 31 of 44 patients. They had a mean exotropia of 19.3 ± 5.3° and a mean occurrence of 40% (range 3-99%). There was a moderate correlation between the magnitude of exotropia and its occurrence (r = 0.59). In 13 patients the occurrence of exotropia was <1%; they were deemed to have an exophoria only. In 35 of 44 cases, families reported an occurrence of intermittent exotropia greater than that measured by the eye tracking glasses. CONCLUSIONS: Eye tracking glasses may be a useful tool for quantifying the severity of intermittent exotropia and for defining more precisely its clinical features.