Current source density analysis of linear and non-linear components of the primate electroretinogram

对灵长类动物视网膜电图线性和非线性成分进行电流源密度分析

阅读:1

Abstract

1. We have used the method of current source density analysis to locate the generators of harmonic electroretinogram (ERG) responses to contrast-modulated pattern and uniform-field stimuli in the primate retina. 2. Sinusoidal steady-state analysis was used, with a stimulus temporal frequency of 8 Hz. Fundamental and second-harmonic response components were measured for the uniform-field response. The second harmonic of the average of contrast-reversal pattern responses obtained at a series of spatial phases was also determined in the same experiments. In addition, retinal tissue resistance was measured. All of these measurements were obtained at a series of equally spaced depths in the retina. 3. Retinal resistivity was not observed to vary systematically with depth. In addition, any plausible undetected inhomogeneities of resistivity with depth were found to slightly affect the relative magnitudes of estimated current sources and sinks, but to have little effect on their localization. 4. In a given penetration, the phase lag of each harmonic component was relatively constant with depth in most cases; however the magnitude of this phase lag sometimes varied in different penetrations. To compare data from different penetrations, the constant phase lag for each harmonic was estimated, and the response data phase-shifted so as to bring all data into a standard (cosine) phase. 5. The resulting current source density analyses were found to be quite consistent in overall form for different penetrations and in different animals. These data were averaged to obtain a final estimate of the depth profiles for generators of different ERG components. 6. The uniform-field fundamental response was found to have a predominant source-sink pair in the distal half of the retina (receptor layer to outer plexiform layer). The pattern (second-harmonic) response generators had a quite different depth profile, consisting mainly of a source-sink pair in the proximal 20% of the retina (encompassing the nerve fibre layer to the middle of the inner plexiform layer). The uniform-field second-harmonic response showed a current source density (CSD) depth profile with multiple sources/sinks, as if it contained contributions from the other two.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。