Improvement of exercise tolerance in cardiopulmonary testing with sustained safety after regular training in outpatients with systolic heart failure (NYHA III) and an implantable cardioverter-defibrillator. Prospective 18-month randomized study

一项前瞻性随机研究,旨在评估门诊收缩性心力衰竭(NYHA III级)且植入式心脏复律除颤器患者在接受规律训练后,心肺功能测试中的运动耐量是否得到改善,以及其安全性是否得以维持。该研究为期18个月。

阅读:1

Abstract

INTRODUCTION: The aim of the study was to evaluate the impact of individual training on the level of physical capacity and echocardiographic parameters in patients with systolic heart failure (SHF), NYHA III and an implantable cardioverter-defibrillator (ICD). MATERIAL AND METHODS: The study included 84 patients with SHF, randomly assigned to one of two groups: with regular training (ICD-Ex) and a control group (ICD-control). The ICD-Ex group participated in a hospital rehabilitation program which after discharge was individually continued for 6 months in an outpatient setting. The ICD-control group participated in a training program during hospitalization, but after discharge did not perform any controlled activities. Prior to discharge, at 6 and 18 months cardiopulmonary exercise testing (CPX), standard echocardiographic examination and the 6-minute walk test (6-MWT) were performed in all patients. RESULTS: After 18 months in the ICD-Ex group most of the CPX parameters improved significantly (VO(2) peak, ml/kg/min: 13.0 ±4.1 vs. 15.9 ±6.1, p < 0.0017; VCO(2) peak, l/min: 1.14 ±0.34 vs. 1.58 ±0.65, p < 0.0008; Watt: 74.5 ±29.7 vs. 92.6 ±39.1, p < 0.0006; METs 3.72 ±1.81 vs. 4.35 ±1.46, p < 0.0131). In the ICD-control group no significant improvement of any parameter was observed. Left ventricular systolic dimensions remained significantly lower at 18 months only in the ICD-Ex group (49.5 ±11.0 vs. 43.4 ±10.0, p < 0.011). Left ventricular ejection fraction in both groups significantly increased at 6 and 18 months compared to baseline (ICD-Ex: 25.07 ±5.4 vs. 31.4 ±9.2, p < 0.001, vs. 30.9 ±8.9, p < 0.002, ICD-C: 25.1 ±8.3 vs. 29.2 ±7.7, p < 0.012 vs. 30.1 ±9.1, p < 0.005). Distance of the 6-MWT was significantly improved after 6 and 18 months in the ICD-Ex group and was overall longer than in the ICD-control group (491 ±127 vs. 423 ±114 m, p < 0.04). CONCLUSIONS: An individual, 6-month training program, properly controlled in patients with SHF and an implanted ICD, was safe and resulted in a significant improvement of exercise tolerance and capacity and echocardiographic parameters.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。