NAPL-water interfacial area as a function of fluid saturation measured with the interfacial partitioning tracer test method

采用界面分配示踪剂试验方法测定NAPL-水界面面积与流体饱和度的关系

阅读:1

Abstract

The presence of organic immiscible liquids such as chlorinated solvents and fuels continues to be a primary source of risk for many hazardous waste sites. In this study, the standard miscible-displacement interfacial partitioning tracer test (IPTT) method was used for the first time to measure NAPL-water interfacial areas for a range of saturations. Multiple measurements were conducted for a natural quartz sand, with tetrachloroethene as the representative NAPL. The interfacial areas increased with decreasing water saturation. The measurements compared well to interfacial areas measured for the same sand with two alternative tracer methods, the mass-distribution batch method and the two-phase flow method. Measurements obtained with all three tracer-based methods exhibit a relatively large degree of variability. Thus, it is important to employ replication when using these methods. In contrast, interfacial areas measured with x-ray microtomography exhibit very small variability. However, the measured interfacial areas do not capture the contribution of surface-roughness to film-associated interfacial area. Each method has associated advantages and disadvantages, and it is important to be cognizant of them during their application.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。