Simultaneous Analysis and Efficient Separation of Anabolic Androgenic Steroids in Dietary Supplement by a Validated HPTLC Method

采用经验证的高效薄层色谱法同时分析和高效分离膳食补充剂中的合成代谢雄激素类固醇

阅读:1

Abstract

BACKGROUND: Using sports supplements is common among athletes. The presence of anabolic steroids in sports supplements as a hormonal contaminant can increase production efficiency. Since anabolic steroids cause health problems and result in positive doping tests in athletes, it is important to investigate their presence in the supplement preparations consumed by athletes. OBJECTIVES: This paper aims to simultaneously determine ten anabolic steroids by high-performance thin-layer chromatography (HPTLC) method in sports supplements. METHODS: Chromatographic analysis was conducted on glass silica gel 60F254 plates. The extracts loaded on silica gel plates are subjected to programed multiple development (PMD) to separate anabolic androgenic steroids (AASs). Densitometric scanning is carried out at the wavelength of 245 and 366nm. The method was validated according to the ICH guidelines. RESULTS: Spots at retardation factor (Rf) 0.72 (elution system 1), 0.4 (elution system 1), 0.29 (elution system 2), 0.25 (elution system 2), 0.1 (elution system 1), 0.65 (elution system 2), 0.59 (elution system 1), 0.44 (elution system 1), 0.8 (elution system 3), and 0.82 (elution system 3) values were recognized as 19-nor androstenedione, 19-nortestosterone, methyl testosterone, clostebol, stanozolol, trenbolone enanthate, oxymetholone, oxandrolone, testosterone enanthate, and nandrolone decanoate, respectively. The linear ranges were 25 - 250 μg/mL for oxymetholone, 7 - 50 μg/mL for 19-nor androstenedione, 19-nortestosterone, and oxandrolone, and 3 - 20 μg/mL for methyl testosterone, clostebol, stanozolol, trenbolone enanthate, testosterone enanthate, and nandrolone decanoate. The developed method is validated by acceptable precision (CV < 20%) and good accuracy (94% < R < 114%). The value of limit of detection (LOD) for all derivatives was in the range of 0.02 - 0.16 μg/spot (20-160 μg/g of supplement), while limit of quantitation (LOQ) was found to be in the range of 0.06 - 0.5 μg/spot (60 - 500 μg/g of supplement). Fifty sports supplement samples as real sample were collected and analyzed. None of the samples screened positive using the HPTLC method. CONCLUSIONS: In the present study, the fast, cheap, and simple HPTLC method could be used for the multi-residue analysis of ten anabolic androgenic steroids in sports supplements.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。