Lower pass threshold (≥93%) for critical congenital heart disease screening at high altitude prevents repeat screening and reduces false positives

在高海拔地区,降低先天性心脏病筛查的合格阈值(≥93%)可以防止重复筛查并减少假阳性结果。

阅读:1

Abstract

OBJECTIVE: We evaluated first screen pass rate for two pass thresholds for critical congenital heart disease (CCHD) oxygen saturation (SpO(2)) screening at higher altitude. STUDY DESIGN: A retrospective cohort of 948 newborns underwent CCHD screening near sea-level (n = 463) vs 6250 ft altitude (n = 485) over 3 years. Standard SpO(2) pass threshold ≥95% and lower SpO(2) pass threshold ≥93% (high-altitude screen) were applied to first measurements to compare pass frequencies. RESULTS: The median SpO(2) was lower in high-altitude newborns (96% vs 99%-p < 0.001). The high-altitude newborns passed the AAP algorithm first screen less often (89.3% vs 99.6%-p < 0.001). With the high-altitude algorithm, 98% of high-altitude newborns passed the first screen. CONCLUSION: Lowering the SpO(2) pass threshold by 2% at >6000 ft, significantly increased first screen pass rate. Adjustments for altitude may reduce nursing time to conduct repeat measurements and prevent transfers for echocardiograms. Larger studies are necessary to assess impact on false negatives.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。